A peptide Certificate of Analysis (COA) is the document in which a manufacturer or testing lab certifies, for a specific batch, what a research compound is and how pure it measured. To read one, check four things in order: the identity specs (compound name, CAS number, amino acid sequence), the HPLC purity result against its acceptance criterion (typically 99%+), the observed molecular weight against the theoretical value (within ±0.5 Da), and the batch number, which must match the vial label. The sections below walk through each part of the document, the specs a complete COA should include, and the red flags that mean a batch should be rejected.

October 2026 update: purity versus quantity

The purity line on a COA is a ratio, not an amount. It reports what share of the material the HPLC detector sees is the target peptide. It does not report how much peptide is in the vial. A COA that lists purity and identity but no content line leaves the fill amount unverified, however high the purity reads.

Quantity shows up on a COA in one of two forms. Net peptide content is the share of the powder's mass that is peptide, with the rest made up of counterions such as trifluoroacetate or acetate, bound water and residual salts; amino acid analysis or elemental nitrogen analysis is the usual method. Content per vial, also called assay or fill, compares the measured peptide mass in a container with the labeled amount, using gravimetric measurement or quantitative HPLC against a reference standard.

So a vial can read 99% pure and still be under-filled. When reading the document, look for a line such as "Net peptide content (amino acid analysis): 84.1%" or "Content (quantitative HPLC vs reference standard): 97.6% of label claim," and check that it names its method. The peptide purity guide explains why the HPLC number and the content number cannot be converted into each other.

What is the difference between peptide identity and purity on a COA?

Identity, purity and content are three different lines on a COA, each answering its own question with its own method. Reading them as interchangeable is the most common COA mistake: a strong purity result does not confirm the molecule, and a matching mass does not confirm how clean or how full the vial is.

COA line Question it answers Method Example wording Acceptance check
Identity Is this the expected molecule? Mass spectrometry (ESI or MALDI) "Observed mass consistent with theoretical MW 1419.56" Within ±0.5 Da (high resolution) or ±1 Da
Purity What share of detected material is the target? Reverse-phase HPLC, UV at 214 nm "Purity (HPLC): 99.3%" At or above stated criterion, often 99%
Content How much peptide is present? Amino acid analysis, nitrogen analysis, quantitative HPLC "Net peptide content: 84.1%" or "97.6% of label claim" Method named, value against label

The example molecular weight, 1419.56 g/mol, is BPC-157's. For a larger molecule such as GLP-3, at 4731.33 g/mol, the same identity check applies, though the mass spectrum shows a broader isotopic envelope, as the mass spectrometry section below notes.

What is a peptide COA?

A Certificate of Analysis (CoA) is a formal document issued by a manufacturer or testing laboratory that certifies a specific batch of material meets defined quality specifications. For research peptides, the CoA documents analytical test results including identity confirmation, purity determination, and physical characteristics.

A CoA is core documentation for research chemical traceability and quality record-keeping. The document includes the compound name, batch number, manufacturing date, molecular formula, molecular weight, CAS number, and amino acid sequence for peptides. Test results sections detail analytical findings from HPLC purity analysis, mass spectrometry identity confirmation, endotoxin testing, and other quality assays. Acceptance criteria define the pass/fail thresholds for each test, while actual results show the measured values. Analyst signatures and quality assurance approval indicate the batch passed all specifications. CoAs enable researchers to verify compound identity and quality before experimental use.

What information appears in the compound identification section?

The identification section provides basic descriptive information about the compound. This includes the product name, chemical name, molecular formula (showing atom counts), molecular weight (in Daltons), and CAS Registry Number (unique chemical identifier).

For peptides, this section lists the amino acid sequence in standard single-letter or three-letter notation. The batch number identifies the specific production lot, enabling traceability to manufacturing records. Manufacturing and testing dates indicate when the compound was produced and analyzed. Storage conditions specify recommended temperature and handling requirements.

Physical appearance describes the visual characteristics—typically white to off-white lyophilized powder for peptides. Standard practice is for identification information to match exactly between the CoA and product label. Researchers should verify that the CAS number and sequence match the intended compound, checking for typographical errors that could indicate mislabeling. For example, the CoA for a peptide such as BPC-157 or TB500 should list the full amino acid sequence next to a CAS number that matches the product label exactly. Any discrepancies between CoA and product require resolution before use.

How do you interpret HPLC purity results?

HPLC purity results appear as both numerical percentages and chromatographic data. The purity percentage represents the area of the target peptide peak divided by total integrated peak area, multiplied by 100 — a chromatographic purity estimate under the method's detection conditions, not a measure of total sample mass, since residual salts, water, and material the method does not detect fall outside it.

Values should meet or exceed stated specifications—typically ≥99% for research-grade peptides. The chromatogram section or attachment displays the actual separation with retention time on the x-axis and detector response on the y-axis. The main peak represents the target compound; earlier peaks indicate more hydrophilic impurities, later peaks indicate hydrophobic impurities or aggregates.

Peak shape provides quality information—symmetrical peaks indicate pure compounds while tailing suggests degradation or chromatographic issues. The report includes integration parameters including start and end times for peak detection. Reviewing the chromatogram itself complements the numerical value, revealing impurity profiles that percentages alone obscure. Acceptance criteria specify minimum purity thresholds. Research-grade compounds like Glutathione and Ipamorelin publish their measured HPLC purity directly on the CoA. Results below acceptance indicate batch failure.

What does mass spectrometry data confirm?

Mass spectrometry data confirms molecular identity through accurate mass measurement. The CoA reports the theoretical molecular weight calculated from amino acid composition and the observed molecular weight from mass spectrometric analysis.

These values should agree within ±0.5 Da for high-resolution instruments or ±1 Da for standard instruments. The mass spectrum attachment shows the molecular ion peak—typically [M+H]+ for protonated peptides—and fragment ions if tandem MS was performed. Mass accuracy within tolerance shows the batch is consistent with the expected amino acid composition; it does not by itself establish residue order, since different sequences built from the same amino acids share a mass, and sequence-level methods such as tandem MS are required for that.

Deviations indicate synthesis errors, modifications, or contaminants. Intact mass measurement is the standard first-line identity check for synthetic peptides. The CoA may also report purity by mass spec, though HPLC remains the standard for peptide quantification. Isotopic distribution patterns in the mass spectrum provide additional identity confirmation, matching theoretical distributions calculated from elemental composition. Larger incretin analogs such as GLP-1 (Semaglutide) and GLP-3 show broader isotopic envelopes than small peptides, which is worth keeping in mind when reading their mass spectra.

What specs should a peptide COA include? Acceptance criteria, explained

Acceptance criteria define the pass/fail thresholds that determine whether a batch meets quality specifications. Each test on the CoA has corresponding acceptance criteria. For purity, acceptance might be 99%+. For mass accuracy, acceptance might be ±0.5 Da from theoretical.

For endotoxin, acceptance might be <0.1 EU/mg. These criteria derive from regulatory guidelines, industry standards, and internal quality policies. Acceptance criteria should be appropriate for the intended application. Results meeting acceptance criteria indicate the batch passed. Results outside acceptance indicate failure, requiring rejection or retesting. Acceptance criteria ensure consistency across batches and suppliers. They establish objective quality standards rather than subjective judgments. Researchers should review acceptance criteria to ensure they meet experimental requirements—some applications may require tighter specifications than standard research grades. CoAs clearly distinguish acceptance criteria from actual results, typically listing both side-by-side.

How do you verify batch traceability?

Batch traceability connects the specific vial in your laboratory to manufacturing and testing records. The CoA batch number must match the batch number on the product vial label. This number links to manufacturing records including synthesis protocols, reagent lots, equipment used, and environmental conditions during production.

Testing records include instrument calibration data, reference standards used, analyst identification, and raw analytical data. Traceability matters because it enables investigation if issues arise—if a batch produces unexpected results, traceability allows review of the complete production history. Retain CoAs with laboratory records for the duration of your research plus regulatory retention periods. For publication, maintain CoAs as supplementary documentation of compound characterization. Valid traceability requires that batch numbers are unique and permanently associated with test results. Photocopies or digital scans maintain traceability if originals are lost, though authenticated originals are preferred for regulatory submissions.

What red flags indicate a questionable CoA?

Several warning signs suggest a CoA may not represent legitimate quality testing. Missing or generic information—lacking specific batch numbers, dates, or analyst names—indicates potential template reuse without actual testing. Perfect round numbers like exactly 99.00% purity suggest fabrication rather than measurement.

Mismatched units or calculations that do not align with reported values indicate errors or fraud. Absence of chromatograms or spectra when claimed as tested raises questions about whether analysis actually occurred. Spelling errors, formatting inconsistencies, or unprofessional presentation suggest lack of quality systems. Fraudulent CoAs circulate in this market. Verify CoA authenticity by contacting the testing laboratory directly using contact information from their official website—not contact information on the potentially fraudulent document. Reputable suppliers welcome verification and provide additional documentation upon request.


Research Use Only: All compounds sold by Amino Foundry are intended exclusively for laboratory research. Not for human use. These products are not drugs, supplements, or food. Statements have not been evaluated by the FDA. Must be 21+ to purchase.

Reference

Common questions

A peptide certificate of analysis (COA) is a batch-specific document in which a manufacturer or testing lab reports each test run on a lot: its method, acceptance criterion and measured result. A complete COA covers identity by mass spectrometry, purity by HPLC, and ideally net peptide content, with a batch number matching the vial.

Research only

Research updates

Get new-compound announcements and subscriber deals. For research purposes only.